<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN">
FIELD CHANGE INSTRUCTION
ISDN
RELEASE 6.3 VERSION 1.5 (SX200Elx T1)
This
Field Change Instruction (FCI) is intended to assist Customer Service and Installation Personnel involved in the
installation and support of the Mitel® ISDN PRI Card.
NOTICE
The information
contained in this document is believed to be accurate in all respects but is
not warranted by Mitel Corporation (Mitel). The information is subject to
change without notice and should not be construed in any way as a commitment by
Mitel or any of its affiliates or subsidiaries. Mitel and its affiliates and
subsidiaries assume no responsibility for any errors or omissions in this
document. Revisions of this document or new editions of it may be issued to
incorporate changes.
®, ™- Trademark of Mitel Corporation.
© Copyright 2000, Mitel Corporation. All rights reserved.
Part Number 56001461 Issue 3 13, DEC, 2000
Printed In Canada.
1. SOFTWARE HISTORY OF ISDN Release 6.
2. ENHANCEMENTS INCLUDED IN MAINTENANCE RELEASES
6. INSTALLATION AND UPGRADE NOTES
7. FIXES INCLUDED IN PRI CARD RELEASE 6.3 VERSION (1.2)
8. CUSTOMER REPORTED PROBLEMS NOT FIXED IN THIS SOFTWARE RELEASE.
This FCI details
enhancements ISDN Release 6.3, software Version 1.5. Hardware and documentation
requirements for this software release are also discussed.
1. SOFTWARE HISTORY OF ISDN Release 6.
Version Level |
Date |
Reason For Issue |
6.0.1.17 |
April 2000 |
This is the first release </TBODY> |
6.1.1.3 |
August 2000 |
UR 1 Release |
6.2.1.11 |
Oct 2000 |
This is the first release |
6.3.1.2 |
Nov 2000 |
This is the second release |
6.3.1.5 |
Dec 2000 |
This is the third release |
2. ENHANCEMENTS INCLUDED IN MAINTENANCE RELEASES
This section lists changes that have been made to system
operation in this software release.
2.1 CHANGES IN ISDN RELEASE 6.3 Version 1.5
General
Overview
The ISDN release 6 software load combines all of the various
ISDN products into one software load.
Software
The
Release 6.3 version 1.5 software is shipped on CD ROM and will be labeled for
the platform it is intended for.
New
PRI cards are shipped with pre-installed software, which includes the boot
load, ISDN application and a default IMAT database. New Network Gateways are
shipped with pre-installed software but no IMAT database.
Software
upgrades for the PRI Cards are performed by connecting a Win95 or 98 personal
computer running Dial-Up Networking 1.3 to the PRI Card Interface Assembly
serial port and transferring files in the PRI_Install folder on the CD using
the IMAT software upgrade program.
Minimum levels of
Application software to function correctly with the ISDN Release 6.2 Version 1.11
are tabled below.
<TBODY> APPLICATIONS |
SOFTWARE LEVEL REQUIREMENTS |
COMMENTS |
SX-200Elx |
LW17 Release 4 |
|
IMAT |
6.2.1.11 |
|
Microsoft Windows Dial-up Networking (msdun12.exe or medun13.exe) on IMAT PC |
1.2 or 1.3 |
WIN95,98
Only </TBODY> |
Qsig Outgoing Calling Name |
LW18 Release 1 |
|
SX-200
LW17 Rel. 4 Options Required
The
following SX-200 PBX system features and options must be enabled or modified
for the full functionality of the ISDN PRI card to work correctly:
Form 4 System Options (PBX Programming)
NOTE: Verify that
the cabinet is a SX-200 ELx Rev 4.3 or greater, and that the software is
LIGHTWARE 17 Release 4.0 or greater.
·
Enable Number of Links (option 96)
·
NFAS (option 91) (If Required)
·
D-Channel Backup (option 92) (Optional)
·
Min/Max (option 94) (Optional)
·
Auto Min/Max (option 95) (Optional)
·
Remote Lan Access (LW 18) (Optional)
·
Qsig Basic Call
·
Calling Name (Optional) Requires
LW18 Release 1
4. HARDWARE REQUIREMENTS
This section details
Mitel’s requirements for the PRI Card to function. Also included in this section
are details related to any new hardware or major changes to existing hardware.
Finally the recommended hardware/circuit card field levels are laid out.
4.1 RECOMMENDED HARDWARE/CIRCUIT CARD FIELD
LEVEL’S
This section identifies Mitel’s recommended field levels for
the ISDN PRI and related hardware. To ensure the best level of service; Mitel
encourages customers to meet these hardware levels. Recommended field levels on
hardware may change without notice. The
MCC compatibilities listed below are only when the PRI Card is installed in the
Control Bay. See TSB on Mitelonline for further details.
SX200
Hardware |
Part Number |
Revision Of Cabinet Required |
200 ELX Cabinet |
9109-600-002-NA |
4.3 or higher |
PRI Card with module |
9109-615-101-NA |
Includes PRI card, T1/E1 module, and
PRI card software. Requires SX-200 ELx cabinet Rev 4.3 or greater and
LIGHTWARE 17 Release 4.0 or greater |
MCC III ML
S4 |
9109-610-001-NA |
141967303R1 1.3 142760301R1 1.5 141967303R2 2.4 |
MCC III ML
S3 |
9109-610-002-NA |
142760302R1 1.3 141967304R1 1.3 141967304R2 2.4 |
MCC III EL
S4 |
9109-610-101-NA |
142759301R1 1.4 141967301R1 1.4 141967301R2 2.5 |
MCC III EL
S3 |
9109-610-102-NA |
142759302R1 1.2 141967302R1 1.4 141967302R2 2.5 |
MCC III ELX
S3 |
9109-610-202-NA |
142759304R1 1.2 |
Part Number |
Title |
Notes |
9109-953-090-NA |
SX-200 EL/ML LIGHTWARE 18 Release 1.0 Technical Documentation CDROM |
Contains CD-ROM Technical
Documentation covering all features. |
51000403 |
SX-200 Technician's Handbook
|
Provides a quick reference to maintenance
commands, frequently used procedures, programming aids, troubleshooting
flowcharts, and installation information. |
6. INSTALLATION AND UPGRADE NOTES
6.1 NEW INSTALLATION Release 6.2 Version 1.11 or later
Refer
to the appropriate section of the CD-ROM Documentation for detailed
information.
IMPORTANT
When Upgrading
Follow this order
When upgrading from a release earlier than 6, it is strongly
suggested that you follow these steps.
NOTE: It is very important to follow the
above order. This will prevent serious complication such as constant resets. If
this occurs, contact technical support.
6.2 RELEASE 6.3 SOFTWARE UPGRADE
Refer to the appropriate section
of the CD-ROM Documentation and IMAT on line help for detailed
information.
7. FIXES INCLUDED IN PRI CARD RELEASE 6.3 VERSION (1.5)
Problem # 605 Intermitten reset of pri card and call
failure
Problem
# 621 Cannot complete calls with Qsig master/Qsig slave without Rlan enabled in
Dimensions
Problem
# 620 UK-PRI Calls to 144(BT
Chargecard)fail
Problem
# 629 QSIG integration with Fujitsu
supporting Setup Acknowledge
Problem # 619 CPN substitutions incorrect for ext beginning with "0"
Problem
# 631 Unable to communicate to PRI
card with maintenance terminal.